性――交――性――乱丨日韩视频网址丨日韩一区二区精品视频丨久久久青青草丨极品美女销魂一区二区三区丨欧美大波乳人伦免费视频丨国产精品高跟丝袜一区丨亚色九九九全国免费视频丨亚洲美女色视频丨亚洲中文字幕永久在线不卡丨92看片淫黄大片欧美看国产片丨欧美日一本丨国产精品av一区二区三区不卡蜜丨亚洲日本一本dvd高清丨国产网红主播av国内精品丨四虎影丨中文字幕无线码免费人妻丨欧美乱淫丨中文有码无码人妻在线短视频丨中文精品久久久久人妻不卡丨亚洲精品无码av人在线观看丨亚洲精品小视频丨被窝影院午夜无码国产丨久久天堂无码av网站丨综合色在线视频

產(chǎn)品列表PRODUCTS LIST

首頁>產(chǎn)品中心>日本光明北川式氣體檢測管>氣體快速檢測管>122SA環(huán)氧乙烷CH2CH2O氣體檢測管122SA ETHYLENE OXIDE 0.01-4%

環(huán)氧乙烷CH2CH2O氣體檢測管122SA ETHYLENE OXIDE 0.01-4%

簡要描述:

環(huán)氧乙烷CH2CH2O氣體檢測管122SA ETHYLENE OXIDE 0.01-4%,檢測管可用于交通:電車、飛機、船舶、公共汽車或長途車等,醫(yī)療機構(gòu):醫(yī)院、診療所、保健所等,事務(wù)所:辦公室、會議室、大廳、演藝室等,學(xué)校:實驗室、教室的空氣污染等,公共場所:電影院、劇場、商場、飯店和酒店等,體育與休閑:游泳池、訓(xùn)練場、室內(nèi)體育設(shè)施等,針對突發(fā)公共衛(wèi)生事件應(yīng)急監(jiān)測推出的氣體應(yīng)急檢測箱等

更新時間:2025-09-03

發(fā)郵件給我們:554328895@qq.com

分享到: 1
在線留言
環(huán)氧乙烷CH2CH2O氣體檢測管122SA ETHYLENE OXIDE 0.01-4%

環(huán)氧乙烷CH2CH2O氣體檢測管122SA ETHYLENE OXIDE 0.01-4%

Tube 22SA

1. PERFORMANCE
1) Measuring range :1.0-4.0% 0.01-1.8%
Number of pump strokes :1/2(50ml) 1(100ml)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :50 ppm
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Orange→Dark brown
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
Potassium dichomate is reduced.
CH2CH2O+Cr6++H2SO4→Cr3+
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
????
(White)
DEHUMIDIFIER
GAS To pump
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.1
0.01
%
122SA ETHYLENE OXIDE
Substance Interference ppm Coexistence
Alcohols FIG.1 Similar stain is produced. Higher readings are given.
Esters FIG.2 〃〃
Ketones 〃〃
Aromatic hydrocarbons 〃〃
Halogenated hydrocarbons WPahleo leb rroewang.ent is discoloured to 0.5% 〃
Ethanol is indicated with half the sensitivity, Ethyl acetate has the same sensitivity with Ethylene oxide.
(NOTE)
1)If the discolouration exceeds the scale, replace the tube with new one and pull the handle at half stroke(to 50mr
line). And read the concentration.
2)Correct the reading value with the temperature correction table first, and convert the value into an actual
concentration by using the conversion scale shown in the instruction sheet.
0
2.0
1.5
1.0
0.5
Methanol〔%〕?
FIG.1 Influence of Methanol
Ethylene oxide indicating value 〔%〕
0.2 0.4 0.6
Coexistence
Interference
0
2.0
1.5
1.0
0.5
Ethyl acetate〔%〕?
FIG.2 Influence of Ethyl acetate
Ethylene oxide indicating value 〔%〕
0.2 0.4 0.6
Coexistence
Interference
TEMPERATURE CORRECTION TABLE
Scale True Concentration (%)
Readings 0℃ 10℃ 20℃ 30℃ 40℃
(%) (32°F) (50°F) (68°F) (86°F) (104°F)
1.8 - 2.00 1.80 1.70 1.64
1.6 2.06 1.78 1.60 1.50 1.46
1.4 1.84 1.58 1.40 1.35 1.28
1.2 1.60 1.34 1.20 1.14 1.09
1.0 1.31 1.12 1.00 0.93 0.88
0.8 1.08 0.91 0.80 0.73 0.68
0.6 0.86 0.70 0.60 0.54 0.49
0.4 0.63 0.49 0.40 0.34 0.30
0.2 0.36 0.26 0.20 0.16 0.13
0.1 0.20 0.14 0.10 0.08 0.06
0.01 0.05 0.02 0.01 0.01 0.01
Conversion
scale (I)
(50mR actual value)?
(100mR concentration scale)?